AlproJet-DD |Daily Cleaning & Disinfection For Dental Suction System (Aspirator) And Spittoon Bowl
Daily Maintenance of Dental Aspiration systems and Spittoon bowl
AlproJet-DD is a concentrated liquid .
All dental suction and Vacuum Aspiration systems With or without Amalgam separator.
It Cleans, Disinfects and Deodorizes
It is compatible with all materials .
It is Foam-free cleaning concentrate liquid for all types of suction system and amalgam separator
Efficacy :
- bactericidal
- yeasticidal
- virus-inactivating
- Dissolves biofilm and prevents formation of sludge through blood and proteins
- The solution for contaminated suction systems – provides reliable protection against infection
- certified by VAH (Association for Applied Hygiene) /DGHM (German Society for Hygiene and Micro- biology), meets the DGHM requirements and EN-standards for the disinfection of instruments
- Recommended by leading equipment manufacturers because , It has Certified material compatibility .
Features :
- Aldehyde-free ,chlorine-free and phenol-free
- Foaming Free and cleaning disinfectant concentrate based on quaternary ammonium salts.
- High dirt-dissolving power towards deposits , saliva residues and drilling dusts.
- Good material compatibility.
- Even very low concentrations are sufficient to achieve rapid effectiveness.
- Clean , Disinfect and Deodorize
- Environmentally friendly.
- Pleasant odor
- Highly effective and fast at low concentrations.
- Low application concentration (5%)
- Highly intensive cleaning effect against deposits and sludge
Application For Dental Suction System :
For the reliable cleaning, disinfection and care it is recommended that For one application , you should use 2 Liter of a 5 % solution .
- Prepare 2 liter of Alprojet-DD 5 % solution to be ready for use .
- We Recommend the suction of Ready To Use Solution of 1 liter per treatment unit .
- The Spittoon Bowel Must be disinfected with at least 250ml solution .
For 1 liter preparation ( 50 ml From Alprojet-DD + 950 ML warm water )
- Alprojet-DD is used 1 – 2 times per day (at noon and in the evening).
- Let take effect for at least 10-30 minutes .
- The disinfectant solution of Alprojet-DD can remain in the system until the next restart of the assembly .
Rinse aspiration tubes and spittoon bowl thoroughly with water just before starting to work.
Please follow the manufacturer‘s instructions as .We Recommend Rinsing the system with at least 2 liter cold water prior to the first patient and following the expiry of the exposure time .
Spittoon Bowl can be cleaned and disinfected with other Surface disinfectant solution or wipes ( Minuten wipes or PlastiSept Wipes OR Alprocleaner solution )
- Description
- Institutional Order (B2B)
- Presentation
- Video
- Characteristics
- Application
- Composition
- Caution
- Sizes
- Scientific
Description
AlproJet-DD is a concentrated liquid preparation for the cleaning as well as maintenance of all dental suction and Vacuum Aspiration systems With or without Amalgam separator.
Daily Maintenance of Dental Aspiration systems and Spittoon bowl Too .
It Cleans , Disinfects and Deodorizes
It is compatible with all materials and recommended for all types of Suction systems
Moreover, It is Foam-free cleaning concentrate for all types of suction system and amalgam separator
Alprojet-DD For Daily Cleaning And Maintenance of Dental Suction units .
Disinfecting liquid concentrate , for the daily cleaning and maintenance of dental aspiration systems with and without amalgam separator.
Alprojet-DD has appropriate action times – whether rapid or more prolonged – based on the specific requirements of the equipment involved.
Finally , Approved amongst others by Dentsply Sirona.
Alprojet-DD Has Triple Actions for Dental Suction System
It cleans , disinfects and deodorizes .
The product contains active substances that were carefully selected and blended together to achieve synergistic effect against bacteria, fungi besides viruses leaving the system clean and odor-free .
Application For Dental Suction System :
For the reliable cleaning, disinfection and care it is recommended that For one application , you should use 2 Liter of a 5 % solution .
- first ,Prepare 2 liter of Alprojet-DD 5 % solution to be ready for use .
- We Recommend the suction of Ready To Use Solution of 1 liter per treatment unit .
- The Spittoon Bowel Must be disinfected with at least 250ml solution .
For 1 liter preparation ( 50 ml From Alprojet-DD + 950 ML warm water )
- Alprojet-DD is used 1 – 2 times per day (at noon and in the evening).
- Let take effect for at least 30 minutes .
- The disinfectant solution of Alprojet-DD can remain in the system until the next restart of the assembly .
Rinse aspiration tubes and spittoon bowl thoroughly with water just before starting to work.
Please follow the manufacturer‘s instructions as well .We Recommend Rinsing the system with at least 2 liter cold water prior to the first patient and following the expiry of the exposure time .
Furthermore ,Spittoon Bowl can be cleaned and disinfected with other Surface disinfectant solution or wipes ( Minuten wipes or PlastiSept Wipes OR Alprocleaner solution )
Finally, If you will use Alprojet-DD ( the daily maintenance ) and Alprojet-W ( weekly maintenance ) as Routine Maintenance of the suction unit , maintain 2 hour interval between the cleaning and the disinfection to inhibit the neutralization reaction between the Both solution .
Fields of application
Foam-free liquid concentrate for simultaneous cleaning, disinfection, deodorization and care of all suction systems and amalgam separators
For daily cleaning and disinfection of dental aspiration systems of all designs (including saliva aspirator / with and without amalgam separator).
Active ingredient basis
Highly effective aldehyde-free, phenol-free and chlorine-free cleaning- and disinfection concentrate based on Quaternary ammonium compounds (QAC ) , tensides and alkaline carriers
(100 g of the solution contain): 7.5 g Dimethyl dioctyl ammonium chloride, 0.6 g Benzyl dimethyl dodecyl ammonium chloride
Compatibility
AlproJet-DD is highly compatible with materials such as plastics, rubber and non-ferrous metals , alloyed steels and others .
Finally , It is Approvals from leading device manufactures
Dental Suction unit disinfectant
Disinfectant for dental suction systems, separators in addition to spittoon bowls and water groups.
Efficacy
- bactericidal
- yeasticidal
- virus-inactivating: limited spectrum of virucidal activity according to EN 16777 against non-enveloped adeno- and noro-viruses as well as all enveloped „blood-borne“ viruses HBV, HCV, HIV and influenza
- Dissolves biofilm and prevents formation of sludge through blood and proteins
- The solution for contaminated suction systems – provides reliable protection against infection
- certified by VAH (Association for Applied Hygiene) /DGHM (German Society for Hygiene and Micro- biology), meets the DGHM requirements and EN-standards for the disinfection of instruments
- Recommended by leading equipment manufacturers because , It has Certified material compatibility .
Disinfectant Concentrate Features :
- Aldehyde-free ,chlorine-free and phenol-free
- Extremely low-foaming and cleaning disinfectant concentrate based on quaternary ammonium salts.
- High dirt-dissolving power towards deposits , saliva residues and drilling dusts.
- Good material compatibility.
- Even very low concentrations are sufficient to achieve rapid effectiveness.
- Clean , Disinfect and Deodorize
- Environmentally friendly.
- Manufacturer: APMD FACTORY UNDER THE LICENSE FROM ALPRO MEDICAL COMPANY IN GERMANY .
- Pleasant odor
- Highly effective and fast at low concentrations.
- Low application concentration (5%)
- Equally important , it is Ideal in combination with Alprojet-W
- Dissolves encrustations of lime scale, prophy powder or prophylaxis pearl products
- Highly intensive cleaning effect against deposits and sludge
Delivery form
- 1 L
- 5 L Canister
Accessories
- AlproJet MixCup.
The water circuit of the dental unit , which supplies water to the instruments and removes waste substances, constitutes a vehicle for the transmission of infections. This is due to the presence of biofilm, a complex aggregation of micro-organisms which develops inside the water mains systems: communities of bacteria from the water flow supplying the unit adhere firmly to the layer of limescale, and proliferate due to various factors which promote their growth and adhesion.
The suction circuit is also an ideal breeding ground for pathogenic micro-organisms, due to the removal of solid and liquid compounds during dental procedures. This makes the scrupulous observation of the dental unit cleaning protocol – disinfection of the suction system in particular – a vital part of dental practice.
Dental Suction System Infection :
The water circuit of the dental unit, which supplies water to the instruments and removes waste substances, constitutes a vehicle for the transmission of infections.
This is due to the presence of biofilm, a complex aggregation of micro-organisms which develops inside the water mains systems: communities of bacteria from the water flow supplying the unit adhere firmly to the layer of limescale, and proliferate due to various factors which promote their growth and adhesion.
The suction circuit is also an ideal breeding ground for pathogenic micro-organisms, due to the removal of solid and liquid compounds during dental procedures.
This makes the scrupulous observation of the dental unit cleaning protocol – disinfection of the suction system in particular – a vital part of dental practice.
The dental unit is where all medical procedures are performed on the patient. As well as being an indispensable component of the dental practice, unfortunately it is also the main vehicle of cross infections between staff and patients, both exposed to pathogenic micro-organisms carried by blood, oral and respiratory secretions and contaminated equipment.
Numerous studies have shown that the dental unit can be colonized by pathogenic micro-organisms in the form of fungi, bacteria or protozoa.
Due to the way that infections are transmitted, the critical points in dentistry are many, and stem from the multitude of microbial agents, the variety of possible infection routes, the type of instruments used, the rapid turnover of patients, and the invasive nature of the procedures performed.
Backflow In Dental Suction :
occur in the following situations
- When they use a saliva ejector holding the tubing above the patient’s head
- When patients close their lips and form a seal around the tip of the ejector that
creates a partial vacuum - When the saliva ejector is used at the same time as other evacuation (high
volume) equipment
take measures to avoid Backflow in dental suction system .
Disinfection of the dental unit : all the steps
To drastically reduce the accumulation and proliferation of bacteria and other pathogenic micro-organisms, a dental unit maintenance protocol should be followed every day.
Frst ,At the start of the day:
- Flushing of the suction lines with high-level disinfectant for two minutes.
- Flushing of each instrument with water for no less than 2 minutes.
Second ,Between patients:
- Cleaning of the surfaces.
- Detergion and decontamination of the surfaces.
- Flushing of each instrument with water for 20-30 seconds.
- Flushing of the suction cannulas with high-level disinfectant for two minutes.
Lastly ,At the end of the day:
- Flushing of the suction lines with high-level disinfectant, leaving it to act overnight if possible.
- Flushing of each instrument with water for at least 2 minutes.
- Cleaning of spittoon outlet filter.
- Removal and cleaning of the suction system filter.
How to choose dental unit disinfectants
- For effective cleaning of the dental unit on a daily basis, it is important to choose disinfectants with appropriate action times – whether rapid or more prolonged – based on the specific requirements of the equipment involved.
- lastly , It is advisable to use mild products with a prolonged action effective against organic material.
Dental Suction Systems Maintenance Notes :
Chlorine-based products should never be used in the suction lines since the chlorine can cause corrosion of metal components in the system.
Oxidizers have been shown to cause mercury to be released from amalgam particles, which can cause water contamination.
Disposable suction traps should be changed weekly or more often if they become clogged.
The used suction traps should not be discarded in the trash since they contain amalgam particles.
A licensed medical/hazardous waste hauler should be used to dispose of the traps, as well as amalgam capsules since they may have traces of mercury left from the mixing process.
Cleaning or disinfection: What’s right for the suction lines?
Advice and contact
-
E-Mail : info@apmdksa.com
I would like to enquire about the following product:
Presentation
Video
Characteristics
Free of Aldehydes & Phenols
Free of Phosphates
Prevents foam formation
Fresh smelling scent
Biodegradable according to the instructions of the Organization for Economic Cooperation and Development (OECD).
Application
Remove cap of dosing section. Fill it with 50 mL. of AlproJet-DD by pressing bottle slightly. Dilute this volume with 950 mL. of water to make 1 Liter 5% ready to use solution. Use 5% solution to rinse the system 1-2 times daily through the spittoon bowl and suck it into the system through the suction pipes.
Composition
Less than 15% Cationic Surfactants
Less than 5% Amphoteric Surfactants
Less than 5% Non-ionic Surfactants
Less than 5% Sodium Carbonate
Dimethyldioctylammonium chloride as disinfecting agent
Caution
Do not mix with other cleaners or disinfectants
Avoid contact with skin and eyes. In case of contact, rinse with plenty of water.
The use of protective gloves is recommended
Sizes
1 Liter Dosage Bottle
5 Liters
Scientific
•Prof. Dr. H. P. Werner, Schwerin, Viruzid (low level), 2015-01
•Dr. H. Brill, Hamburg, VAH incl. EN 13624 + EN 13727, 2006-10; EN 14561 + EN 14562, 2006-10
•Dr. J. Hoffler, Hamburg, EN 13624 + EN 13727, 2009-05
•Prof. Dr. R. Schubert, Frankfurt/M., VAH incl. EN 13624 + EN 13727 + EN 14561 + EN 14562, 2007-02
•Dr. J. Steinmann, Bremen, Adeno, 2006-05; Vaccinia, 2006-04; BVDV, 2003-11; HBsAgVerfahren,2003-10 Virusinaktivierend: behullte Viren incl. HBV, HCV, HIV, Influenza incl. (H1N1,H5N1), Herpes simplex, 2009-08